Time Set - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

4.1.2.2

time set

Description
With this command, you set the system clock.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time set hh:mm:ss <day (1-31)>
{january|february|march|april|may|june|july|august|september|october|november|decembe
r}
<year (2000 - 2035)>
The parameters have the following meaning:
Parameter
hh:mm:ss
day
-
year
Result
The system time is set.
Further notes
You display the settings for the system clock with the
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
Description
Time of day
Day of the month
Month
Year
4.1 System time setting
Range of values / note
Hour, minute, second each sepa-
rated by ":" no link
1 ... 31
january, february, march, april,
may, june, july, august, septem-
ber, october, november, decem-
ber
2000 ... 2035
command.
show time
System time
125