Network protocols
6.6 SNMP
Parameter
ipv4
IPAddress
timeout
Seconds
retries
RetryCount
taglist
TagIdentifier
none
volatile
nonvolatile
port
integer
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
If optional parameters are not specified when configuring, the following defaults apply:
Parameter
taglist
Type of storage
port
Result
The SNMP target address is configured.
Further notes
You delete the SNMP target address with the
You display the SNMP target address with the
You configure the SNMP target parameters with the
You display the SNMP target parameters with the
242
Description
Keyword for an IPv4 address
Value for an IPv4 unicast address
Keyword for the time the SNMP
agent waits for a response before it
repeats the inform request message
Time in seconds
Keyword for the maximum number of
attempts to obtain a response to an
inform request message
Number of attempts
Keyword for tag list
Tag identifier that selects the desti-
nation address for SNMP.
No tag identifier
Specifies whether the settings re-
main following a restart.
Keyword for the port number at
which the SNMP manager receives
traps and inform messages
Port number
no snmp targetaddr
show snmp targetaddr
Range of values
-
Enter a valid IPv4 unicast address.
-
1 ... 1500
-
1 ... 3
-
Specify the tag identifier.
-
volatile
The default settings are used af-
ter a restart.
nonvolatile
The saved settings are used af-
ter a restart.
-
1 ... 65535
Default value
snmp
volatile
162
command.
command.
snmp targetparams
show snmp targetparam
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
:
:
command.
command.