No Event Config - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Diagnostics
10.1 Event and fault handling
To enable the clients, use the
Note
Changing several message types or clients
With each command call, you can only select one message type and one client.
If you want to process several message types or clients, it may be more efficient to first
select the
10.1.10.5

no event config

Description
With this command, you configure which of the various message types of the device will no
longer be stored or forwarded.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no event config
{ cold-warmstart | linkchange | authentication-failure | power-change | faultstate-
change | digital-in | vpn-tunnel | all}
{logtable | syslog | email | trap | faults | digital-out | vpn-tunnel | all}
The parameters have the following meaning:
Parameter
cold-warmstart
linkchange
authentication-failure
power-change
faultstate-change
digital-in
vpn-Tunnel
all
logtable
syslog
email
428
client config
option and then disable individual elements.
all
Description
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a status change in the power supply
Message when there is a status change in the error monitoring
Message when there is a status change of the digital input
Message when there is a connection change (OpenVPN, IPsec, SINEMA RC)
All messages
Client that processes the log entries
Client that sends the messages to the log server
Client that sends the e-mails
command.
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02