Security and authentication
9.2 Firewall
Result
The interval is configured.
Further notes
You display this setting and other information with the
9.2.4.8

idle timeout tcp

Description
With this command, you configure the required period for TCP. If no data exchange takes
place, the TCP connection is terminated automatically when this time has elapsed.
Requirement
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
idle timeout tcp <second(1-4294967295)>
The parameter has the following meaning:
Parameter
second
Result
The interval is configured.
Further notes
You display this setting and other information with the
9.2.4.9

ipv4rule

Description
With this command, you create your own IPv4 rules for the firewall. These IPv4 firewall rules
have a higher priority than the predefined IPv4 firewall rules.
320
Description
Interval in seconds
show firewall information
Range of values / note
1 ... 4294967295
show firewall information
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02