System Location; System Name - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Configuration
3.1 System
3.1.12.11

system location

Description
With this command, you enter the location information for the system.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
system location <location name>
The parameter has the following meaning:
Parameter
location name
Result
The location information is created in the system.
3.1.12.12

system name

Description
This command, you enter a name for the system.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
system name <system name>
90
Description
Input box for the location information
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
max. 255 characters
Configuration Manual, 06/2016, C79000-G8976-C252-11