Configuration
2.1 System
Further notes
You disable automatic logout with the
You display the current timeout setting with the
2.1.9.7

no cli-console-timeout

Description
With this command, you disable the automatic logout.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no cli-console-timeout
Result
Automatic logout is disabled.
Further notes
You enable automatic logout with the
You display the current timeout setting with the
2.1.9.8

system contact

Description
With this command, you enter contact information for the system.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
56
no cli-console-timeout
show cli-console-timeout
command.