10.1.10.8

severity

Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog } { info | warning | critical }
The parameters have the following meaning:
Parameter
mail
log
syslog
info
warning
critical
Result
The settings for sending system event messages are configured.
The "severity" function is enabled.
Further notes
You disable the setting with the
You display the status of this function and other information
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
Description
Specifies the threshold value for send-
ing system event messages by e-mail.
Specifies the threshold value for enter-
ing system event messages in the log
table.
Specifies the threshold value for enter-
ing system event messages in the
Syslog file.
System events are processed as of the
severity level "
Information
System events are processed as of the
severity level "
".
Warning
System events are processed as of the
severity level "
".
Critical
command.
no severity
10.1 Event and fault handling
Range of values / note
-
-
-
-
".
-
-
show events severity
Diagnostics