Smtp-Server - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
no sender mail-address
Result
The e-mail name of the sender is reset.
Further notes
You configure the e-mail name of the sender with the
You display the setting with the
6.10.2.3

smtp-server

Description
With this command, you configure an entry for an SMTP server.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-server {ipv4 <ucast_addr> | fqdn-name <FQDN(100)>} <receiver mail-address>
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
show events sender email
Description
Keyword for an IP address
Value for an IPv4 unicast address
Keyword for a domain name
Network protocols
6.10 SMTP client
.
sender mail-address
command.
Note on the range if values
-
Enter a valid IPv4 unicast ad-
dress.
-
269

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents