Precision Time Protocol (Ptp) Ports - Siemens RUGGEDCOM RX1100P Installation Manual

Table of Contents

Advertisement

Chapter 3
Communication Ports
NOTE
On power-up, all serial RJ45 ports default to RS485 mode. Each port can be individually set to RS232,
RS485 or RS422 mode through ROX . For more information, refer to the ROX User Guide for the
RX1100P.
NOTE
For information about how to connect devices configured to run in RS485 mode, refer to
"Connecting Multiple RS485
All serial ports feature an LED that indicates the current state of the port.
State
Green
Off
For specifications on serial ports, refer to
The following is the pin-out description for RJ45 serial ports:
8
Figure 25: Serial RJ45 Port Pin Configuration
a
Connected internally.
b
In RS232 mode, this pin enters a high impedance state. A DTE that asserts RTS will see CTS asserted, although the device will not perform hardware flow
control.
Section 3.8

Precision Time Protocol (PTP) Ports

The optional Precision Time Protocol (PTP) card for the RX1100P provides accurate time synchronization across
local and wide area networks. The PTP card is capable of using a variety of time synchronization methods
including Network Time Protocol (NTP), IRIG-B, and IEEE 1588, making it a flexible product for new and existing
installations.
22
Devices".
Description
Link activity detected
No link detected
Section 4.6, "Serial Port
1
Shield
Specifications".
Pin
RS232 Mode
RS485 Mode
a
1
DSR/RI
a
2
DCD
3
DTR
4
Common (Isolated) Ground
5
RX
6
TX
ab
7
CTS
b
8
RTS
Chassis Ground
Precision Time Protocol (PTP) Ports
RUGGEDCOM RX1100P
Installation Guide
Section 3.11,
RS422 Mode
RX-
RX+
TX/RX+
TX+
TX/RX-
TX-