ACX Series Universal Access Router Configuration Guide
Table 209: show ptp global-information Output Fields (continued)
Field Name
ESMC QL From Clock Class
l
Clock Class/ESMC QL
SNMP Trap Status
Slave Parameters
Master Parameters
Number of Slaves
Number of Masters
Stateful Ports
Transparent-clock-config
2940
Field Description
Denotes whether the conversion from clock class to QL is enabled or disabled.
Denotes the user defined clock class to QL conversion.
Denotes the SNMP trap generation status (Enabled or Disabled).
Parameters configured on the slave clock:
—Log mean interval between synchronization messages requested during unicast
Sync Interval
negotiation.
—Log mean interval between delay-response messages requested during
Delay Request Interval
unicast negotiation.
—Log mean interval between announce messages requested during unicast
Announce Interval
negotiation.
—Number of announce messages missed and detected by the slave, resulting
Announce Timeout
in the slave identifying the master as unreachable.
—Length of time a unicast grant is assigned for unicast negotiation.
Grant Duration
Parameters configured on the master clock:
—Log mean interval between synchronization messages sent to a configured manual
Sync Interval
slave.
—Log mean interval between announce messages sent to a configured manual
Announce Interval
slave.
The minimum and maximum parameters below are the minimum and maximum values accepted
during unicast negotiation from remote clients:
—Log
Min Announce Interval
eight seconds. The value should be in the range 0 to 3.
Max Announce Interval
—Maximum acceptable interval between announce messages. The value
should be in the range 0 to 3.
Min Sync Interval
—Minimum acceptable interval between synchronization messages.
—Log
value, which means that the maximum synchronization rate is 128
Max Sync Interval
2
messages per second.
Min Delay Response Interval
Max Delay Response Interval
Clock Step
—Synchronous timing message: one-step or two-step. With two-step, a subsequent
follow-up message is received after the first synchronous message.
Holdover In Specification Time
time for holdover-in-specification state is 86400 seconds (24 hours).
Number of slaves configured on the router.
Number of masters configured on the router.
Total number of interfaces that are configured to be stateful or dynamic. A stateful port functions as
both a master port and a slave port.
Display whether transparent clock is configured.
value, which means that announce messages are sent once every
2
—Minimum acceptable interval between delay-response messages.
—Maximum acceptable interval between delay-response messages.
—Display the status of holdover-in-specification time. The default
Copyright © 2017, Juniper Networks, Inc.