ACX Series Universal Access Router Configuration Guide
2928
Table 205: show protection-group ethernet-ring statistics Output Fields
Field Name
Ethernet Ring Statistics for PG
RAPS event sent
RAPS event received
Local SF
Remote SF
NR event
NR event sent
NR event received
NR-RB event
NR-RB event sent
NR-RB event received
Flush event sent
Flush event received
Local FS event sent
Remote FS event received
Local MS event sent
Field Description
Name of the protection group for which statistics are displayed.
Number of times Ring Automatic Protection Switching (RAPS)
message transmission event occurred locally. This field is
applicable only to MX Series routers.
Number of RAPS messages received and processed by ERP
state-machine and which resulted in state transition. This field
is applicable only to MX Series routers.
Number of times a signal failure has occurred locally.
Number of times a signal failure has occurred anywhere else on
the ring.
Number of times a No Request event has occurred on the ring.
This field is applicable only to EX Series switches.
Number of times a No Request event has occurred locally. This
field is applicable only to MX Series routers.
Number of times a No Request event has occurred anywhere
else on the ring. This field is applicable only to MX Series routers.
Number of times a No Request, Ring Blocked event has occurred
on the ring. This field is applicable only to EX Series switches.
Number of times a No Request, Ring Blocked event has occurred
locally. This field is applicable only to MX Series routers.
Number of times a No Request, Ring Blocked event has occurred
anywhere else on the ring. This field is applicable only to MX
Series routers.
Number of times flush-event RAPS message transmission event
occurred locally. This field is applicable only to MX Series routers.
Number of flush-event RAPS messages received and processed
by the ring instance control process. This field is applicable only
to MX Series routers.
Number of times a forced switch event has occurred locally. This
field is applicable only to MX Series routers.
Number of times a forced switch event has occurred anywhere
else on the ring. This field is applicable only to MX Series routers.
Number of times a manual switch event has occurred locally.
This field is applicable only to MX Series routers.
Copyright © 2017, Juniper Networks, Inc.