Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run
dustproof check-timer day days
The cleaning cycle for the air filtered is configured.
----End

1.5.2 Remonitoring the Cleaning Cycle of the Air Filter

Context
The system generates an alarm about cleaning the air filter. After ensuring that the air filter is
cleaned or does not need to be cleaned, you need to clear the alarm and remonitor the cleaning
cycle of the air filter.
Do as follows on the router:
Procedure
Step 1 Run:
reset dustproof run-time
The alarm is cleared. The cleaning cycle of the air filter is monitored.
----End

1.5.3 Checking the Configuration

Procedure
Step 1 Run:
display dustproof
Information about the air filter is displayed.
----End
Example
Run the display dustproof command. You can view information about the cleaning cycle of
the air filter, the last time when the air filter was cleaned (referring to the time on the router),
how many days the router had been run since the previous cleaning, and how long the alarm
about cleaning the air filter exists. For example:
Issue 01 (2011-10-15)
NOTE
The air filter is a component without memory. All the monitored information is saved on the MPU, which
may be inserted, removed, switched, or replaced during usage. Therefore, the monitoring cycle may differ
from the set cycle, but this does not affect the monitoring function.