cli(config)#
Syntax
Call up the command with the following parameters:
poe pse usage <percent>
The parameters have the following meaning:
Parameter
percent
Result
The value for Usage Threshold is configured.
3.5.3.2

no poe pse usage

Description
With this command, you set the Usage Threshold parameter to the default value of 80%.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
poe pse usage
Result
Usage Threshold is set to 80%.
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Description
Value for Usage Threshold as a percentage.
Configuration
3.5 PoE
97