3.4.7. Replacement of SMB battery

Location of SMB battery
The SMB battery (SMB = serial measurement board) is located on the left hand side of the
frame as shown in the figure below.
xx0700000029
A
B
C
Required equipment
Equipment, etc.
Battery pack
Standard toolkit
Circuit Diagram
Removal, battery
The procedure below details how to remove the SMB battery.
3HAC028197-001 Revision: A
SMB battery cover
SMB battery pack
Battery cable
Spare part no.
3HAC16831-1
-
3HAC025744-001
Action
1. Move the robot to its calibration position.
3 Maintenance
3.4.7. Replacement of SMB battery
Note
Battery includes protection circuits. Replace it
only with given spare part no. or an ABB
approved eqvivalent.
The content is defined in section
toolkit on page
280.
See chapter
Circuit
diagram.
Note
This is done in order to facilitate the
updating of the revolution counter.