Removal, brake release unit
The procedure below details how to remove the brake release unit.
3HAC028197-001 Revision: A
Action
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
2.
esd
WARNING!
The unit is sensitive to ESD, before handling
the unit please observe the safety information
in section
WARNING - The unit is sensitive to
ESD! on page 35
3. Remove the push button guard and thecover,
push button guard from the SMB cover.
4. Open the SMB cover by unscrewing the
attachment screws.
Let the battery stay connected, to avoid the
need of synchronization of the robot!
5. Remove the complete brake release unit
(including brake release unit and bracket)
from the SMB recess, by removing its two
attachment screws.
6. Disconnect the connectors X8, X9 and X10
from the brake release unit.
4.5.2. Replacement of brake release unit
Note
Shown in the figure
Location of brake
release unit on page
214.
The guard must be removed to ensure a
correct refitting of the brake release unit.
Shown in the figure
Location of brake
release unit on page
214.
xx0200000129
A: Connector X8
B: Connector X9
C: Connector X10
D: Push buttons
Location of brake release unit is shown
in the figure
Location of brake release
unit on page
214.
Continues on next page