3 Maintenance
3.6.1. Cleaning, robot
Continued
Required equipment
Equipment, etc.
Steam cleaner
High pressure water cleaner
Do's and don'ts!
The section below specifies some special considerations when cleaning the robot.
Always!
Never!
140
•
Always use cleaning equipment as specified above! Any other cleaning equipment
may shorten the life of paintwork, rust inhibitors, signs, or labels!
•
Always check that all protective covers are fitted to the robot before cleaning!
•
Never point the water jet at bearing seals, contacts, and other seals!
•
Never spray from a distance closer than 0.4 m!
•
Never remove any covers or other protective devices before cleaning the robot!
•
Never use any cleaning agents, for example compressed air or solvents, other than
those specified above!
•
Never spray with a high pressure cleaner onto the sealing cup at the bottom of the
motor 6 spiral cable (item A in the figure Special points)!
•
Although the robot is watertight, avoid spraying connectors and similar items with a
high pressure cleaner!
Art. no.
Note
-
•
Water pressure at nozzle: max.
2,500 kN/m
•
Type of nozzle: fan jet, min. 45°
spread
•
Flow: max. 100 litres/min.
•
Water temperature: max. 80° C
-
•
Max. water pressure on enclosures:
50 kN/m
•
Fan jet nozzle should be used, min.
45° spread
•
Flow: max. 100 litres/min.
3HAC028197-001 Revision: A
2
(25 bar)
2
(0.5 bar)