Replacement Of Smb Battery - ABB IRB 6600 - 225/2.55 type B Product Manual

Articulated robot
Table of Contents

Advertisement

3 Maintenance

3.4.8. Replacement of SMB battery

3.4.8. Replacement of SMB battery
Location of SMB battery
The SMB battery (SMB = serial measurement board) is located on the left hand side of the
frame as shown in the figure below.
Note that the robot is shown with the SMB cover already removed!
xx0200000238
A
B
C
Required equipment
Equipment, etc.
Battery pack
Standard toolkit
Circuit Diagram
Removal, battery
The procedure below details how to remove the SMB battery.
200
SMB battery cover
SMB battery pack
Battery cable
Spare part no.
3HAC 16831-1
-
Action
1. Move the robot to its calibration position.
Note
Battery includes protection circuits. Replace it
only with given spare part no. or an ABB
approved eqvivalent.
The contents are defined in section
toolkit on page 436
in part 2 of the Product
manual.
See chapter
Circuit diagram
manual, reference
information.
Note
This is done in order to facilitate the
updating of the revolution counter.
Continues on next page
3HAC023082-001 Revision: E