[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] flow-control
flow interval
Syntax
flow-interval interval
undo flow-interval
View
Ethernet port view
Parameters
Interval: Interval (in seconds) to perform statistics on port information. This argument ranges from 5 to
300 (in step of 5) and is 300 by default.
Description
Use the flow-interval command to set the interval to perform statistics on port information.
Use the undo flow-interval command to restore the default interval.
By default, this interval is 300 seconds.
When you use the display interface interface-type interface-number command to display the
information of a port, the system performs statistical analysis on the traffic flow passing through the port
during the specified interval and displays the average rates in the interval. For example, if you set the
interval to 100 seconds, the displayed information is as follows:
Last 100 seconds input:
Last 100 seconds output:
Related commands: display interface.
Examples
# Set the interval to perform statistics on the Ethernet 1/0/1 port to 100 seconds.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] flow-interval 100
giant-frame statistics enable
Syntax
giant-frame statistics enable
undo giant-frame statistics enable
View
System view
Parameters
None
0 packets/sec 0 bytes/sec
0 packets/sec 0 bytes/sec
1-18
Need help?
Do you have a question about the s3600 series and is the answer not in the manual?
Questions and answers