Use the poe mode command to configure the PoE mode on the current port.
Use the undo poe mode command to restore the PoE mode on the current port to the default mode.
By default, signal mode is adopted on a port.
Note that the S3600 series Ethernet switches do not support the spare mode currently.
Examples
# Set the PoE mode on Ethernet 1/0/3 to signal.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface Ethernet 1/0/3
[Sysname-Ethernet1/0/3] poe mode signal

poe power-management

Syntax
poe power-management { auto | manual }
undo poe power-management
View
System view
Parameters
auto: Adopts the auto mode, namely, a PoE management mode based on PoE priority of the port.
manual: Adopts the manual mode.
Description
Use the poe power-management command to configure the PoE management mode of port used in
the case of power overloading.
Use the undo poe power-management command to restore the default mode.
By default, the PoE management mode on port is auto.
You can use the poe priority command to set the PoE priority of a port.
Examples
# Configure the PoE management mode on a port to auto, that is, adopt the PoE management mode
based on the PoE priority of the port.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] poe power-management auto
Auto Power Management is enabled