<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] hwtacacs scheme hwt1
[Sysname-hwtacacs-hwt1] secondary authorization 10.163.155.13 49

timer quiet

Syntax
timer quiet minutes
undo timer quiet
View
HWTACACS scheme view
Parameters
minutes: Wait time before primary server state restoration, ranging from 1 to 255 minutes.
Description
Use the timer quiet command to set the time that the switch waits before it tries to re-communicate with
the primary server and restore the status of the primary server to active.
Use the undo timer quiet command to restore the default wait time.
By default, the switch waits five minutes.
Related commands: display hwtacacs.
Examples
# Configure the switch to wait 10 minutes before it tries to restore the status of the primary server to
active.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] hwtacacs scheme hwt1
[Sysname-hwtacacs-hwt1] timer quiet