# Display the summary of dropped packets on all interfaces.
<Sysname> display packet-drop summary
All interfaces:
Packets dropped due to full GBP or insufficient bandwidth: 301
Packets dropped due to FFP: 261
Table 6 Command output
Field
Packets dropped due to full GBP or insufficient bandwidth
Packets dropped due to FFP

flow-interval

Use flow-interval to set the statistics polling interval.
Use undo flow-interval to restore the default.
Syntax
flow-interval interval
undo flow-interval
Default
The statistics polling interval is 300 seconds.
Views
System view
Predefined user roles
network-admin
Parameters
interval: Sets the statistics polling interval, in seconds. The interval is in the range of 5 to 300 and must
be a multiple of 5.
Examples
# Set the statistics polling interval to 100 seconds.
<Sysname> system-view
[Sysname] flow-interval 100

interface

Use interface to enter interface or subinterface view.
Syntax
interface interface-type { interface-number | interface-number.subnumber }
Views
System view
Description
Packets that are dropped because the buffer is used
up or the bandwidth is insufficient.
Packets that are filtered out.