Poe Update - H3C s3600 series Command Manual

Hide thumbs Also See for s3600 series:
Table of Contents

Advertisement

Parameters
None
Description
Use the poe temperature-protection enable command to enable PoE over-temperature protection on
the switch.
Use the undo poe temperature-protection enable command to disable PoE over-temperature
protection on the switch.
The PoE over-temperature protection operates as follows:
The switch disables the PoE feature on all ports when its internal temperature exceeds 65°C (149°F) for
self-protect, and restores the PoE feature settings on all its ports when the temperature drops below
60°C (140°F).
By default, PoE over-temperature protection is enabled on the switch.
You can use the display poe temperature-protection command to display whether PoE
over-temperature protection is enabled on the switch.
Examples
# Disable PoE over-temperature protection on the switch.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] undo poe temperature-protection enable
The temperature protection is disabled.

poe update

Syntax
poe update { refresh | full } filename
View
System view
Parameters
refresh: The refresh update mode is used when the PSE processing software is available. The refresh
update mode is to upgrade the original processing software in the PSE.
full: The full update mode is used when the PSE processing software is damaged. The full update
mode is to delete the original damaged software in the PSE completely and then reload the PoE
processing software.
filename: Update file name, with a length of 1 to 64 characters and with the extension .s19.
Description
Use the poe update command to update the PSE processing software online.