H3C s3600 series Command Manual page 882

Hide thumbs Also See for s3600 series:
Table of Contents

Advertisement

Use the full mode only when the refresh mode fails. In normal cases, use the refresh mode.
When the PSE processing software is damaged (that is, all the PoE commands cannot be
successfully executed), you can use the full mode to update and restore the software.
When the online upgrading procedure is interrupted for some unexpected reason, for example, the
device is restarted due to some errors. If the upgrade in full mode fails after restart, you must
upgrade in full mode after power-off and restart of the device, and then restart the device manually.
In this way, the former PoE configuration is restored.
Examples
# Update the PSE processing software online.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] poe update refresh 0400_001.S19
Update PoE board successfully
update fabric
Syntax
update fabric { file-url | device-name file-url }
View
User view
Parameters
file-url: File path + file name of the host software in the flash memory, a string of 1 to 64 characters. The
specified PSE processing software is a file with the extension .s19.
device-name: Specified device in the fabric, in the format of unit[NO.]>flash:, which means that the
target file is saved in the flash of this device.
Description
Use the update fabric command to upgrade the PSE processing software of the fabric switch remotely
on any device in the fabric.
Examples
# Upgrade the PSE processing software poe2046.s19 in the flash of unit 2 to upgrade the PSE
processing software of all the units in the fabric.
<Sysname> update fabric unit2>flash:/poe2046.s19
This will update the Fabric. Continue? [Y/N] y
The software is verifying ...
The result of verification is :
Unit ID
Free space(bytes)
1
2588900
Enough
Version comparison
Y
Y
1-11