cnfalmcnt
To configure the collection of Time Division Multiplex (TDM) line statistics, use the cnfalmcnt
command in the VoIP switching/trunking, switched AAL2 PVC, and AAL2 trunking operating modes.
Syntax Description
-ds1
line-num
-sev
alarm-severity
-lcv15
lcv-15min
-lcv24
lcv-24hr
-les15
les-15min
-les24
les-24hr
-lses15
lses-15min
-lses24
lses-24hr
-crc15
crc-15min
-crc24
crc-24hr
-crces15
Cisco VISM Installation and Configuration Guide
5-72
cnfalmcnt -ds1 line-num -sev alarm-severity -lcv15 lcv-15min -lcv24 lcv-24hr -les15 les-15min
-les24 les-24hr -lses15 lses-15min -lses24 lses-24hr -crc15 crc-15min -crc24 crc-24hr -crces15
crces-15min -crces24 crces-24hr -crcses15 crcses-15min -crcses24 crcses-24hr -sefs15
sefs-15min -sefs24 sefs-24hr -aiss15 aiss-15min -aiss24 aiss-24hr -uas15 uas-15min -uas24
uas-24hr
The mandatory line-num argument identifier.
Line number of the T1 or E1 line for which you want to display alarms. It can be
in the range from 1 to 8.
The alarm-severity argument identifier.
Alarm severity. It can be one of the following values:
1 = Minor
2 = Major
The lcv-15min argument identifier.
The number of line code violations encountered by the line interface in the current
15-minute interval. It can be in the range from 0 to 2147483647.
The lcv-24hr argument identifier.
The number of line code violations in the last 24-hour period encountered by the
interface. It can be in the range from 0 to 2147483647.
The les-15min argument identifier.
The line code violation errored seconds in the last 15 minutes encountered by the
interface. It can be in the range from 0 to 2147483647.
The les-24min argument identifier.
The line code violation errored seconds in the last 24 hours encountered by the
interface. It can be in the range from 0 to 2147483647.
The lses-15min argument identifier.
The line code violation severely errored seconds in the last 15 minutes encountered
by the interface. It can be in the range from 0 to 2147483647.
The lses-24hr argument identifier.
The line code violation severely errored seconds in the last 24 hours encountered
by the interface. It can be in the range from 0 to 2147483647.
The crc-15min argument identifier.
The number of CRC code violations in the last 15 minutes encountered by the
interface. It can be in the range from 0 to 2147483647.
The crc-24hr argument identifier.
The number of CRC code violations in the last 24 hours encountered by the
interface. It can be in the range from 0 to 2147483647.
The crces-15min argument identifier.