Type
Severity
Facility
RPD_MIRROR_ERROR
System Log Message
Description
Type
Severity
Facility
Cause
Action
RPD_MIRROR_VERSION_MISMATCH
System Log Message
Description
Type
Severity
Facility
Action
RPD_MLD_ACCOUNTING_OFF
System Log Message
Description
Type
Severity
Facility
RPD_MLD_ACCOUNTING_ON
System Log Message
Copyright © 2010, Juniper Networks, Inc.
Error: An error occurred
warning
LOG_DAEMON
Unable to establish mirror connection between Routing Engines: error-message
The routing protocol process (rpd) could not establish the mirror connection (which
supports nonstop routing) between the master and backup Routing Engines.
Error: An error occurred
warning
LOG_DAEMON
The master and backup Routing Engines are running incompatible versions of the Junos
OS .
Update the Junos OS to compatible versions on the master and backup Routing Engines.
Versions of mirror software on Routing Engines are incompatible: error-message
While trying to establish the mirror connection between the master and backup Routing
Engines (which supports nonstop routing), the routing protocol process (rpd) determined
that the versions of Junos OS on the Routing Engines were incompatible.
Error: An error occurred
warning
LOG_DAEMON
Update the Junos OS to compatible versions on the master and backup Routing Engines.
interface-name time
The Multicast Listener Discovery (MLD) accounting for the indicated interface was
disabled at the indicated time.
Event: This message reports an event, not an error
info
LOG_DAEMON
interface-name time
Chapter 73: RPD System Log Messages