Action
CHASSISD_CFEB_POWER_FAILURE
System Log Message
Description
Type
Severity
Facility
Action
CHASSISD_CLEAR_CONFIG_ERROR
System Log Message
Description
Type
Severity
Facility
Cause
Action
CHASSISD_CLOCK_FAILURE
System Log Message
Description
Type
Severity
Copyright © 2010, Juniper Networks, Inc.
Event: This message reports an event, not an error
error
LOG_DAEMON
The Routing Engine paired with the indicated control board is still online.
Take the Routing Engine offline before taking the control board offline.
function-name: unable to turn state power for CFEB cfeb-slot
The chassis process (chassisd) could not turn on or turn off the power to the indicated
Compact Forwarding Engine Board (CFEB).
Error: An error occurred
error
LOG_DAEMON
Contact your technical support representative.
function-name: status
The chassis process (chassisd) encountered an error while trying to clear the state
information associated with a copy of the management process (mgd) that it spawned
to commit the rescue configuration. The commit operation succeeded or failed as
indicated.
Error: An error occurred
error
LOG_DAEMON
An internal software failure occurred.
Contact your technical support representative.
function-name: fru-name error-message
The chassis process (chassisd) determined that the indicated clock source failed in the
indicated way.
Error: An error occurred
error