Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 Reference Manual page 261

System log messages reference
Table of Contents

Advertisement

Action
CHASSISD_PSU_OVERLOAD
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_PSU_TEMPERATURE
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_PSU_VOLTAGE
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_RANGE_CHECK
System Log Message
Description
Type
Severity
Copyright © 2010, Juniper Networks, Inc.
Check the status of the input connections.
Overload condition for power supply pem-slot (status bits: 0xstatus-code);
The indicated power supply unit (PSU) reported an output voltage overload condition.
Event: This message reports an event, not an error
warning
LOG_DAEMON
There might have been excessive load on the PSU.
Temperature check bit set for power supply pem-slot; airflow might be inadequate
The chassis process (chassisd) detected that the 'temperature check bit' was set in the
status bit mask for the indicated power supply unit (PSU).
Event: This message reports an event, not an error
warning
LOG_DAEMON
The PSU might have exceeded its temperature threshold, possibly because the airflow
through it was inadequate.
Power supply pem-slot reports problem; check output voltage
The indicated power supply unit (PSU) reported a problem with its output voltage.
Event: This message reports an event, not an error
warning
LOG_DAEMON
There might have been excessive load on the PSU.
function-name: '0xvalue' is invalid value for object-name (out of range)
The indicated value was outside the valid range of values for the indicated object.
Error: An error occurred
error