Facility
CHASSISD_PSD_RELEASE_MASTERSHIP
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_PSU_ERROR
System Log Message
Description
Type
Severity
Facility
CHASSISD_PSU_FAN_FAIL
System Log Message
Description
Type
Severity
Facility
CHASSISD_PSU_INPUT_BAD
System Log Message
Description
Type
Severity
Facility
196
LOG_DAEMON
Backup Routing Engine became master, because JUNOS version of former master did
not match RSD master
The chassis process (chassisd) running on the master Routing Engine on a System-Domain
routing node relinquished mastership to the backup Routing Engine in the PSD.
Event: This message reports an event, not an error
notice
LOG_DAEMON
The version of the Junos OS on the master Routing Engine did not match the version on
the RSD platform's master Routing Engine. The version on the backup Routing Engine
did match the RSD platform.
error-message power supply pem-slot (status bits: 0xstatus-code); status failure
The chassis process (chassisd) detected the indicated error condition for the indicated
power supply unit (PSU).
Event: This message reports an event, not an error
warning
LOG_DAEMON
Fan Fail for power supply pem-slot
PSU Fan fail bit is set in the status for the indicated power supply unit (PSU)
Error: An error occurred
warning
LOG_DAEMON
error-message power supply pem-slot (status bits: 0xstatus-code); Input failure
The chassis process (chassisd) detected the input voltage/warning fault condition for
the indicated power supply unit (PSU).
Event: This message reports an event, not an error
warning
LOG_DAEMON