Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 Reference Manual page 266

System log messages reference
Table of Contents

Advertisement

Junos 10.3 System Log Messages Reference
CHASSISD_SHUTDOWN_NOTICE
System Log Message
Description
Type
Severity
Facility
CHASSISD_SIB_INVALID_SLOT
System Log Message
Description
Type
Severity
Facility
Action
CHASSISD_SIGPIPE
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_SMB_ERROR
System Log Message
Description
Type
Severity
Facility
202
Shutdown reason: reason
Although the chassis process (chassisd) normally does not exit or shut down except
when the Routing Engine reboots, it shut down for the indicated reason.
Event: This message reports an event, not an error
warning
LOG_DAEMON
fru-name in invalid slot slot
The chassis process (chassisd) detected the presence of the switch interface board
(SIB) in an invalid slot. The SIB remains offline.
Error: An error occurred
error
LOG_DAEMON
Contact your technical support representative.
SIGPIPE received
The chassis process (chassisd) received a signal indicating that its attempt to write to
a pipe failed because the reader (which could be another process or thread) did not exist.
Event: This message reports an event, not an error
error
LOG_DAEMON
The entity at the other end of the pipe exited or closed the connection.
smb_read: fpga download not complete: val return-value, action
The system management bus (SMB) could not download field-programmable gate array
(FPGA) information and returned the indicated status code. The chassis process
(chassisd) took the indicated action.
Error: An error occurred
error
LOG_DAEMON
Copyright © 2010, Juniper Networks, Inc.