CHASSISD_OVER_TEMP_SHUTDOWN_TIME
System Log Message
Description
Type
Severity
Facility
Action
CHASSISD_PARSE_COMPLETE
System Log Message
Description
Type
Severity
Facility
CHASSISD_PCI_ERROR
System Log Message
Description
Type
Severity
Facility
Cause
Action
CHASSISD_PEER_UNCONNECTED
System Log Message
Description
Type
Copyright © 2010, Juniper Networks, Inc.
Chassis temperature above temperature degrees C description (> duration seconds);
powering down all FRUs
The chassis process (chassisd) shut down the routing platform because the temperature
of one or more components exceeded the indicated threshold temperature for the
indicated amount of time. Continued operation at the excessive temperature could
damage the routing platform.
Error: An error occurred
critical
LOG_DAEMON
Increase cooling in the area around the chassis.
Using new configuration
The chassis process (chassisd) successfully parsed its configuration file.
Event: This message reports an event, not an error
info
LOG_DAEMON
function-name: error-message
While performing an operation on the PCI bus, the chassis process (chassisd) encountered
the indicated error.
Error: An error occurred
error
LOG_DAEMON
A software or a hardware problem occurred.
Contact your technical support representative.
function-name: peer not connected
The chassis process (chassisd) processed a packet for a peer with an invalid or missing
connection.
Event: This message reports an event, not an error
Chapter 18: CHASSISD System Log Messages
189
Need help?
Do you have a question about the JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 and is the answer not in the manual?
Questions and answers