CHASSISD_FM_ERROR_F13_FB_TXP
System Log Message
Description
Type
Severity
Facility
Action
CHASSISD_FM_ERROR_F13_FB_TX_VC
System Log Message
Description
Type
Severity
Facility
Action
CHASSISD_FM_ERROR_F13_VC_PWR
System Log Message
Description
Type
Severity
Facility
156
F13SIBsib-slot_FB_fiber-bundle LCC lcc ST_SIB_Lto-lcc-sib is error-message
In a Tx-Plus routing matrix, the fiber-optic cable between each Switch Interface Board
in a T1600 routing node (called a ST-SIB-L) must connect to a specific SIB port on the
TX-Plus Matrix platform (called a F13SIB). The cable connected at the indicated F13SIB
had the indicated error.
Error: An error occurred
error
LOG_DAEMON
Contact your technical support representative.
error-message on F13SIBfrom-sfc-sib_FBfiber-bundle VCSEL vcsel Channel vcsel-channel
connected to LCC lcc SIB_L to-lcc-sib
In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the routing node that houses the indicated F13SIB
detected the indicated error as packets that were traveling in the indicated direction were
translated between electrical and optical media.
Error: An error occurred
error
LOG_DAEMON
Contact your technical support representative.
FM: High power difference at F13SIBfrom-sfc-sib_FBfiber-bundle VCSEL vcsel Channel
vcsel-channel connected to LCC lcc SIB_Lsib-slot
In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the SFC routing node that houses the indicated F13SIB
detected higher than configured receive power difference levels on the indicated
fiber-bundles connected to the indicated LCC ST-SIB-L.
Error: An error occurred
error
LOG_DAEMON