CHASSISD_PEM_OVERLOAD
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_PEM_TEMPERATURE
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_PEM_VOLTAGE
System Log Message
Description
Type
Severity
Facility
Cause
Copyright © 2010, Juniper Networks, Inc.
On the T1600 router, the T1600-FPC4 ES Flexible PIC Concentrator (FPC) requires that
at least one three-input 240-A power supply be installed. The chassis process (chassisd)
did not power on the T1600-FPC4 ES in the indicated slot because the required power
supply is not installed.
Error: An error occurred
error
LOG_DAEMON
Install at least one three-input 240-A power supply.
Overload condition for power supply pem-slot (status bits: 0xstatus-code);
The indicated power entry module (PEM) reported an output voltage overload condition.
Event: This message reports an event, not an error
warning
LOG_DAEMON
There might have been excessive load on the PEM.
Temperature check bit set for power supply pem-slot; airflow might be inadequate
The chassis process (chassisd) detected that the 'temperature check bit' was set in the
status bit mask for the indicated power entry module (PEM).
Event: This message reports an event, not an error
warning
LOG_DAEMON
The PEM might have exceeded its temperature threshold, possibly because the airflow
through it was inadequate.
Power supply pem-slot reports problem; check output voltage
The indicated power entry module (PEM) reported a problem with its output voltage.
Event: This message reports an event, not an error
warning
LOG_DAEMON
There might have been excessive load on the PEM.