CHAPTER 17
CFMD System Log Messages
CFMD_CCM_DEFECT_CROSS_CONNECT
System Log Message
Description
Type
Severity
Facility
Cause
Action
CFMD_CCM_DEFECT_ERROR
System Log Message
Description
Type
Severity
Facility
Cause
Copyright © 2010, Juniper Networks, Inc.
This chapter describes messages with the
connectivity-fault management (CFM) process (cfmd), which supports Operation,
Administration, and Maintenance (OAM) functions that are defined in the Institute of
Electrical and Electronics Engineers (IEEE) 802.1ag standard for Ethernet interfaces.
CFM defect: error-message
A connectivity-fault management (CFM) maintenance endpoint (MEP) received a
continuity check message (CCM) that had an incorrect maintenance association (MA)
ID or a maintenance domain (MD) level lower than that of the MEP, each of which
indicates a cross-connect error.
Event: This message reports an event, not an error
error
ANY
The configuration is invalid.
Check whether the configured MD name, format, and level, or the MA name or format,
is different from the remote endpoint.
CFM defect: error-message
A connectivity-fault management (CFM) maintenance endpoint (MEP) received a
continuity check message (CCM) with an incorrect transmission interval or MEP ID, which
indicates a configuration error.
Event: This message reports an event, not an error
error
ANY
The configuration is invalid.
prefix. They are generated by the
CFMD