CHASSISD_PIPE_WRITE_ERROR
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_POWER_CHECK
System Log Message
Description
Type
Severity
Facility
CHASSISD_POWER_EVENT
System Log Message
Description
Type
Severity
Facility
Cause
CHASSISD_POWER_RATINGS_EXCEEDED
System Log Message
Description
Type
Severity
Copyright © 2010, Juniper Networks, Inc.
Pipe write error: error-message
The chassis process (chassisd) experienced a fatal error while writing to a pipe.
Error: An error occurred
error
LOG_DAEMON
There is no reader for the pipe.
fru-name fru-slot not powering up
The chassis process (chassisd) could not power up the indicated component
(field-replaceable unit, or FRU), because the FRU did not respond.
Error: An error occurred
error
LOG_DAEMON
Unable to turn off power to fru-name fru-slot; a stand-alone test jumper might be installed
The chassis process (chassisd) could not turn off power to the indicated component
(field-replaceable unit, or FRU).
Event: This message reports an event, not an error
warning
LOG_DAEMON
A common reason is that a standalone test jumper is installed.
PIM/module in slot fru-slot left offline to avoid exceeding chassis power ratings
The chassis process (chassisd) did not bring online the component (field-replaceable
unit, or FRU) in the indicated slot, because doing so causes the total power demand of
components in the chassis to exceed the chassis' power ratings. On a J-series Services
Router, the component is a Physical Interface Module (PIM) or other module that installs
in a PIM slot.
Error: An error occurred
error
Chapter 18: CHASSISD System Log Messages
195

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.3 - software

Table of Contents