Xerox ColorQube 9303 Series Service Manual page 597

Table of Contents

Advertisement

Table 1 Status messages - to F
Status
UI Message
Code
Reason for Message
-
89-561-00 NVM entries for RALPH
media registration cali-
bration got corrupted or
reset
-
91-632-00 Print head 1 has changed
since last boot
-
91-633-00 Print head 2 has changed
since last boot
-
91-634-00 Print head 3 has changed
since last boot
-
91-635-00 Print head 4 has changed
since last boot
-
91-636-00 The IOD automatic image
maintenance tool has
tried repeatedly to run
and has failed enough to
exceed the disabled limi-
tation, or has been manu-
ally disabled via
diagnostics
-
91-637-00 IOD Y run out NVRAM
parameters are reset
-
91-638-00 IOD chronic jets are
detected
-
91-639-00 Sent once per cold purge.
Sent when the overall
purge, which might
request multiple heads to
be purged, is requested.
A cold purge is performed
at power up. That is, the
ink in the system is cold,
it is warmed up, then a
purge is performed
-
91-640-00 Sent once per warm
purge. Sent when the
overall purge, which
might request multiple
heads to be purge, is
requested. A warm purge
is performed during the
lifetime of a power on
session. The ink is
already up to temp, then
the print heads are
purged
ColorQube® 9303 Family
Reference / Action
UI Message
Refer to
OF 12
Service Code
-
RAP
-
-
-
-
If the problem persists, perform
the
91-636-00
RAP
-
-
-
-
If the problem persists, perform
the
91-637-00
RAP
-
Perform the
91-638-00
RAP
-
No service action required
-
-
-
-
No service action required
-
-
-
February 2013
2-573
Table 1 Status messages - to F
Status
Code
Reason for Message
Reference / Action
91-641-00 A freeze off means that
No service action required
one or more, print heads
are allowed to cool down
so that the ink is in a solid
state. This would then be
followed by a cold purge.
The freeze off would be
communicated by the
freeze off DC status
updates, and the cold
purges that would follow
would be communicated
by the cold purge DC sta-
tus updates
91-642-00 Sent when a cold purge
No service action required
for head 1 has completed
91-643-00 Sent when a cold purge
No service action required
for head 2 has completed
91-644-00 Sent when a cold purge
No service action required
for head 3 has completed
91-645-00 Sent when a cold purge
No service action required
for head 4 has completed
91-646-00 Sent when a warm purge
No service action required
for head 1 has completed
91-647-00 Sent when a warm purge
No service action required
for head 2 has completed
91-648-00 Sent when a warm purge
No service action required
for head 3 has completed
91-649-00 Sent when a warm purge
No service action required
for head 4 has completed
91-650-00 Head 1 freeze off has
No service action required
completed
91-651-00 Head 2 freeze off has
No service action required
completed
91-652-00 Head 3 freeze off has
No service action required
completed
91-653-00 Head 4 freeze off has
No service action required
completed
91-840-00 IME in jet substitution and
No service action required.
single sided print mode.
Increments the AIF
counter by 1
Status Indicator RAPs
OF 4b