12-450-00-171, 12-456-00-171 to 12-459-00-171 HVF Ejector
Module RAP
12-450-00-171 The ejector module motor has stalled
12-456-00-171 The ejector module did not return to the home position.
12-457-00-171 The ejector module did not move from the home position.
12-458-00-171 The ejector module did not return to the out position.
12-459-00-171 The ejector module did not move from the out position.
Initial Actions
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
14. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Check for damage or obstructions that would prevent the ejector module from operating
correctly.
Check the ribbon cable on the ejector for kinks and potential breaks in the conductors.
Go to
12K-171
HVF Initialization Failure RAP to determine when the fault occurs.
Check the harness to the ejector unit and the connectors under the unit.
Procedure
Figure 1
shows the location of the components.
Enter the
dC330
code 12-184, ejector home sensor, Q12-184. Stack the
move the stapler unit inboard. This action moves the stapler unit inboard, and moves the ejec-
tor module to the out position. The display changes.
Y
N
The ejector module moved to the out position.
Y
N
Go to
WD
12.15. Check the wiring and repair as necessary,
ejector motor, MOT12-236. Refer to:
GP 10
How to Check a Motor.
12A-171, HVF Power Distribution RAP.
01L
0V Distribution RAP
Install new components as necessary:
Ejector assembly,
PL 12.110 Item
HVF PWB,
PL 12.140 Item
Go to
WD
12.11. Check the wiring and repair as necessary,
home sensor, Q12-184. Refer to:
GP 11
How to Check a Sensor.
12A-171, HVF Power Distribution RAP.
01L
0V Distribution RAP
Install new components as necessary:
Ejector assembly,
PL 12.110 Item
A
ColorQube® 9303 Family
dC330
code 12-249 to
REP
1.1. Check the
2.
2.
REP
1.1. Check the ejector
2.
A
HVF PWB,
PL 12.140 Item
Exit diagnostics mode, selecting the re-boot option. This returns the ejector module to the
home position. Enter the
dC330
code, 12-249 to move the stapler unit inboard. The display changes.
Y
N
Go to
WD
12.11. Check the wiring and repair as necessary,
out sensor, Q12-185. Refer to:
GP 11
How to Check a Sensor.
12A-171, HVF Power Distribution RAP.
01L
0V Distribution RAP
Install new components as necessary:
Ejector assembly,
PL 12.110 Item
HVF PWB,
PL 12.140 Item
Exit the diagnostics mode, selecting the re-boot option. This returns the ejector module to the
home position. Enter the
dC330
the
dC330
code, 12-249 to move the stapler unit inboard. The display changes condition
for a few seconds.
Y
N
Go to
WD
12.11. Check the wiring and repair as necessary,
Refer to:
GP 10
How to Check a Motor.
12A-171, HVF Power Distribution RAP.
01L
0V Distribution RAP
Install new components as necessary:
Ejector assembly,
PL 12.110 Item
HVF PWB,
PL 12.140 Item
Perform
SCP 5
Final Actions.
February 2013
12-450-00-171, 12-456-00-171 to 12-459-00-171
2-147
2.
code, 12-185, ejector out sensor, Q12-185. Stack the
REP
1.1. Check the ejector
2.
2.
code 12-096, ejector motor encoder sensor, Q12-096. Stack
REP
1.1. Check Q12-096.
2.
2.