7.
Figure
3. Remove the upper exit guide.
1
Twist the upper exit guide
and lift upwards.
Figure 3 Upper exit guide removal.
Replacement
The replacement procedure is the reverse of the removal procedure.
ColorQube® 9303 Family

REP 12.15-171 HVF Rear Tamper Assembly

Parts List on
PL
12.110.
Removal
Take care during this procedure. Sharp edges may be present that can cause injury.
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
1.
Remove the rear cover
REP
2.
Remove the right side-cover
3.
Remove the ejector assembly
4.
Remove the front tamper assembly,
5.
Remove the pressing and support motor,
February 2013
4-139
WARNING
WARNING
GP
14. Disconnect the power cord
12.1-171.
REP
12.5-171.
REP
12.6-171.
REP
12.11-171.
Figure
1.
2
Disconnect the motor and
1
encoder harness.
Remove 2 screws.
Figure 1 Motor removal
Repairs/Adjustments
REP 12.14-171, REP 12.15-171