REP 62.9 Input Module Angle Sensor

Parts List on
PL 62.15
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the scanner top cover,
REP
2.
Figure
1, remove the input module angle sensor.
3
Disconnect the sensor from
the harness and remove.
Figure 1 Input module angle sensor
Replacement
1.
Reverse the removal procedures to replace the input module angle sensor.
2.
When replacing the input module angle sensor, ensure that the lugs on the sensor are
located in the slot of the frame before tightening the screw.
Repairs/Adjustments
REP 62.9, REP 62.10
WARNING
GP
14. Disconnect the power cord
WARNING
62.2.
2
Depress the actuator
to release the sensor.
1
Remove one screw.

REP 62.10 LED Exposure Lamps

Parts List on
PL 62.15
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the CVT glass,
2.
Remove the CVT ramp and document glass assembly
3.
Figure
1. Remove the LED exposure lamp(s).
February 2013
4-256
WARNING
GP
14. Disconnect the power cord
WARNING
REP
62.3.
REP
62.3.
ColorQube® 9303 Family