Figure 3 Component location
ColorQube® 9303 Family
Tri-folder entry sensor
Q12-164
February 2013
2-127
12-185-00-171 to 12-187-00-171 Tri-Folder Exit Sensor and
Assist Sensor RAP
12-185-00-171 The lead edge is late arriving at the tri-folder exit sensor.
12-186-00-171 The trail edge is late leaving the tri-folder exit sensor.
12-187-00-171 The lead edge is late arriving at the tri-folder assist gate sensor.
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
14. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Check for a jam or other obstruction in the tri-folder.
Check the tri-folder for damage.
Procedure
Enter
dC330
code 12-165. Manually actuate the tri-folder assist gate sensor, Q12-165,
1. The display changes.
Y
N
Go to
WD 12.19
and
WD
12.20. Check Q12-165.
Refer to:
GP 11
How to Check a Sensor.
12A-171
HVF Power Distribution RAP.
01L
0V Distribution RAP
Install new components as necessary:
Tri-folder assist gate sensor,
PL 12.215 Item
Tri-folder control PWB,
PL 12.205 Item
BM PWB,
PL 12.175 Item
10.
Enter
dC330
code 12-166. Manually actuate the tri-folder exit sensor, Q12-166,
display changes.
Y
N
Go to
WD 12.19
and
WD
12.20. Check Q12-166.
Refer to:
GP 11
How to Check a Sensor.
12A-171
HVF Power Distribution RAP.
01L
0V Distribution RAP
Install new components as necessary:
Tri-folder exit sensor,
PL 12.215 Item
Tri-folder control PWB,
PL 12.205 Item
BM PWB,
PL 12.175 Item
10.
Enter
dC330
code 12-267 to energize the tri-folder diverter solenoid, SOL12-267. The
noid energizes.
12-183-00-171, 12-184-00-171, 12-185-00-171 to 12-
WARNING
6.
16.
Figure
12.
16.
Status Indicator RAPs
Figure
2. The
sole-

Advertisement