Xerox ColorQube 9303 Series Service Manual page 111

Table of Contents

Advertisement

12-310-00-110, 12-312-00-110, 12-313-00-110 Interlocks
RAP
12-310-00-110 The docking interlock is open during run mode.
12-312-00-110 The top cover interlock is open during run mode.
12-313-00-110 The front door interlock is open during run mode.
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
14. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Take care not to topple the LCSS. The LCSS is unstable when undocked from the
machine. Do not show the customer how to undock the LCSS.
Check the LCSS PWB DIP switch settings, refer to
tings RAP.
Check the following:
The LCSS is docked to the machine.
The LCSS front door is closed.
The LCSS top cover is closed.
Procedure
Go to
WD
12.1. Check for +24V on P/J 302 pin 1. If the voltage is not present, refer to
LCSS Power Distribution RAP and
01L
0V Distribution RAP.
Go to the appropriate RAP:
12-310-00-110 Docking Interlock RAP
12-312-00-110 Top Cover Interlock RAP
12-313-00-110 Front Door Interlock RAP
12-310-00-110 Docking Interlock RAP
Un-dock the LCSS
REP
12.13-110. Check the docking interlock S12-177,
follows:
Check the interlock actuator on the machine is not damaged or missing.
NOTE: The wiring harness passes underneath the docking interlock switch housing. If
this harness is not correctly positioned, the switch can be mis-located, giving intermittent
docking interlock problems.
Enter
dC330
code 12-177, actuate the docking interlock. If the display does not change,
refer to:
GP
13, How to Check a Switch.
P/J302,
LCSS
PWB.
Go to
WD
12.1. Check the wiring between P/J 302 and the docking interlock switch.
If necessary, install a new docking interlock switch,
ColorQube® 9303 Family
WARNING
WARNING
12F-110
LCSS PWB DIP Switch Set-
PL 12.15 Item
PL 12.15 Item
2.
12-312-00-110 Top Cover Interlock RAP
Check the top cover interlock switch S12-197,
Check the switch actuator.
Enter
dC330
code 12-197, actuate the top cover interlock switch. If the display does not
change, refer to:
GP
13, How to Check a switch.
P/J315,
LCSS
PWB.
Go to
WD
12.4. Check the wiring between P/J315 and the top cover interlock switch.
If necessary install a new top cover interlock switch,
12-313-00-110 Front Door Interlock RAP
Check the front door interlock switch S12-303,
Check the switch actuator.
Enter
dC330
code 12-303, actuate the front door interlock switch. If the display does not
change, refer to:
GP
13, How to Check a switch.
P/J302,
LCSS
PWB.
Go to
WD
12.1. Check the wiring between P/J302 and the front door interlock switch.
If necessary install a new front door interlock switch,
Perform
SCP 5
Final Actions.
12D-110
2, as
February 2013
12-310-00-110, 12-312-00-110, 12-313-00-110
2-87
PL 12.75 Item
6, as follows:
PL 12.75 Item
6.
PL 12.75 Item
5, as follows:
PL 12.75 Item
5.
Status Indicator RAPs