IQ 25 Random Spots RAP

Use this RAP when the output has random spots. Refer to
Random spots are usually ink debris from the stripper blade, abatement plenum or printheads.
Spots can appear on the image if the cleaning unit fails to thoroughly clean the drum. Large
spots of primary colours can be caused by a faulty printhead.
Ensure
IQ 1
Image Quality Entry RAP is performed before starting this RAP.
Figure 1 Random spots from incomplete drum cleaning
Image Quality
IQ 25
Figure
1.
February 2013
3-76
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
14. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Take care during this procedure. The stripper blade is very sharp and can cause injury.
Do not clean the stripper blade. The stripper blade is very sharp and can cause injury. If
the stripper blade is dirty a new blade must be installed.
Take care during this procedure. Sharp edges may be present that can cause injury.
Use care when moving the marking unit into the service position when hot. Ink can spill from
the ink reservoir located at the back of the unit if opened with too much force. Cross-colour ink
contamination could also occur.
Do not touch the exposed face of the printheads. Surface contamination or minor damage can
easily make the printhead unusable.
Press the Machine Status button on the keypad, select the Fault tab on the UI, then Cur-
rent Messages. If the message 'Cleaning unit life extended. Image quality may be
impacted' is displayed, install a new cleaning unit,
Check the media. If low grade or recycled media is found, suggest using a better grade of
media. Defects in the media may appear as spots of ink,
Procedure
Print
TP 14
Drum Stripper Blade Test Print. The stripper blade releases between the 35
mm and the 50 mm mark.
Y
N
Install a new stripper blade solenoid,
Perform
dC969
Clean Ink Smears. Print three copies of TP 4 Yellow Solid Fill Test pages
(TP 2 to TP
10). The test pages are good.
Y
N
Install a new stripper blade assembly,
Perform
SCP 5
Final Actions.
Perform the self test routine in
dC959
Cleaning Unit Exerciser. The cleaning unit self test is
successful.
Y
N
Install a new cleaning unit,
PL 94.10 Item
Remove the cleaning unit
PL 94.10 Item
paper debris. The metering blade and roller area are free of paper debris.
Y
N
Remove the paper debris from the metering blade and roller area. Do not wipe the meter-
ing blade.
A
WARNING
WARNING
WARNING
WARNING
CAUTION
CAUTION
PL 94.10 Item
21.
Figure
2.
PL 10.10 Item
3.
PL 10.12 Item
3.
21.
21. Check the metering blade and roller area for
ColorQube® 9303 Family