REP 12.6-110 Tamper Assembly

Parts List on
PL
12.45.
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the LCSS covers
REP
12.1-110.
2.
Prepare to remove the tamper assembly
4
Release the harness from the retainer
next to the paddle motor assembly,
12.25 Item
10.
A
A
2
Disconnect the tamper
motors harnesses.
1
Disconnect 4 sensor harnesses marked A and
release the harnesses from the retainers.
Figure 1 Preparing the tamper assembly
Repairs/Adjustments
REP 12.6-110
WARNING
GP
14. Disconnect the power cord
WARNING
Figure
1.
3
Release the harness
PL
from all retainers along
the tamper assembly.
A
A
3.
Figure
2, remove the tamper assembly.
1
Remove 2 screws
2
Lift the tamper
assembly upwards
and remove from the
LCSS
Figure 2 Removing the tamper assembly
February 2013