Xerox ColorQube 9303 Series Service Manual page 511

Table of Contents

Advertisement

99-360-00 to 99-382-00 PEST Error 12 RAP
99-360-00 Connectors TTM 1 open.
99-361-00 Connector TTM 2 open.
99-362-00 Connector TTM 3 open.
99-365-00 Power supply unit.
99-366-00 Connector, media path driver PWB.
99-370-00 Connector, PS J4AC marking unit.
99-371-00 Connector, PS J5AC.
99-372-00 Connector AC PS heater 3 open.
99-373-00 Connector AC PS fuse 1 open.
99-374-00 Connector AC PS fuse 2 open.
99-375-00 Connector AC PS fuse 3 open.
99-380-00 Fan power supply short.
99-381-00 Fan power supply open.
99-382-00 Fan power supply stalled.
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
14. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Procedure
Refer to
Table
1. Perform the relevant action. For an explanation of PEST codes refer to
dC123.
Table 1 PEST Hard and Soft Fault Codes
Code
Hard/Soft Action
99-360
Hard
This fault code is for future use and is included for reference only.
99-361
Hard
This fault code is for future use and is included for reference only.
99-362
Hard
This fault code is for future use and is included for reference only.
99-365
Hard
Go to the
01A
RAP. Check that the finisher power cord is securely
connected to the IME.
ColorQube® 9303 Family
WARNING
Table 1 PEST Hard and Soft Fault Codes
Code
Hard/Soft Action
99-366
Hard
LCSS: Go to the
RAP.
OCT: Go to the
HVF: Go to the
Finisher Communication Failure RAP.
Check the communication harness between the finisher and PJ904 on
the media path driver PWB.
99-370
Hard
Check that PJ4AC on the power supply is securely connected. Check
the wiring for an open circuit, repair as necessary,
WD
1.1.
99-371
Hard
Check that PJ5AC on the power supply is securely connected. Check
the wiring for an open circuit, repair as necessary,
WD
1.2.
99-372
Hard
This fault code is for future use and is included for reference only.
99-373
Hard
This fault code is for future use and is included for reference only.
99-374
Hard
This fault code is for future use and is included for reference only.
99-375
Hard
This fault code is for future use and is included for reference only.
99-380
Hard
Install a new power supply,
99-381
Hard
Install a new power supply,
99-382
Soft
Install a new power supply,
February 2013
2-487
12-199-00-110
Unexpected Sheet at Finisher Entry
12-701-00-65
Offset Catch Tray Failure RAP.
12-762-00-171, 12-764-00-171, 12-765-00-171
REP
REP
PL 1.15 Item
2.
PL 1.15 Item
2.
PL 1.15 Item
2.
Status Indicator RAPs
99-360-00 to 99-382-00
IME to
1.1. Refer to
1.1. Refer to