Rep 83.4 Horizontal Transport Motor - Xerox ColorQube 9303 Series Service Manual

Table of Contents

Advertisement

3.
Remove the duplex sensor from the underside of the top cover,
Figure 2 Duplex sensor (17) removal
Replacement
1.
The replacement is the reverse of the removal procedure.
2.
When replacing the top cover, place the assembly on a flat surface i.e. a desk with the
curled portion hanging off the desk.
3.
Hold the top cover down in the correct position the entire time the screws are being
installed.
4.
Install and tighten down the screws in each corner first, then install and tighten the
remaining screws.
5.
Perform
dC625
Registration / Preheat Calibration.
Repairs/Adjustments
REP 83.3, REP 83.4
Figure
2.

REP 83.4 Horizontal Transport Motor

Parts List on
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
Take care during this procedure. Motors will become hot during normal operation.
2
1.
Remove the horizontal paper path,
Remove sensor
2.
Prepare to remove the motor,
1
Disconnect har-
ness
February 2013
4-312
PL 82.15
WARNING
WARNING
WARNING
REP
83.1.
Figure
1.
2
Disconnect harness
3
Remove 3 screws
from the cover.
Figure 1 Cover removal
GP
14. Disconnect the power cord
1
Remove the screw
and unclip the har-
ness guide.