Xerox ColorQube 9303 Series Service Manual page 437

Table of Contents

Advertisement

92-501-00 to 92-504-00, 92-519-00 Serial Link Safety
Transient RAP
92-501-00 MpSerialLinkSafetyTransient.
92-502-00 MuSerialLinkSafetyTransient.
92-503-00 MuidSerialLinkSafetyTransient.
92-504-00 DDSerialLinkSafetyTransient.
92-519-00 PsSerialLinkDownTransient.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
14. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the following:
1.
Switch off then switch on the machine,
ColorQube® 9303 Family
WARNING
GP
14.
92-505-00, 92-506-00 Marking Unit Communications Error
RAP
92-505-00 Marker unit communications failure
92-506-00 Marker unit communications failure
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
If the fault 92-505-00 is accompanied by 92-510-00 and 92-575-00. Check for a loss of
connection on the cable between the IME controller and the marking unit driver PWB.
Procedure
Go to
WD 9.7
and
WD
9.10. Check for loose connections between:
The IME controller PWB and the marking unit driver PWB.
Refer to:
PJ903,
IME controller
PWB.
PJ203,
Marking unit driver
If the fault persists, install new components as necessary:
Marking unit driver PWB cable (PJ203),
IME controller PWB,
PL 92.10 Item
Marking unit driver PWB,
February 2013
92-501-00 to 92-504-00, 92-519-00, 92-505-00, 92-
2-413
WARNING
GP
14. Disconnect the power cord. Electricity can cause
PWB.
PL 92.10 Item
14.
1.
PL 92.10 Item
4.
Status Indicator RAPs

Advertisement

Table of Contents
loading