91-848-00 to 91-851-00 IOD Align Calibration Error RAP
91-848-00 IOD align calibration: X stitch measurement limit excessive X stitch was measured
and the align calibration process cannot complete.
91-849-00 IOD align calibration: Y stitch measurement limit excessive Y stitch was measured
and the align calibration process cannot complete.
91-850-00 IOD align calibration: X offset correction limit align calibration resulted in an X stitch
correction value that is too large.
91-851-00 IOD align calibration: Y offset correction limit align calibration resulted in an Y stitch
correction value that is too large.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
14. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Enter
dC612
and print TP 16. Check the stitch identification test pages. A stitch defect is
present
Y
N
Perform
SCP 5
Final Actions
Manually disable the IOD align calibration:
1.
Enter
dC131
NVM read/write NVM ID 490-41 and change value to 3.
2.
Enter
dC971
and start the routine.
3.
Enter
dC612
and print TP 16 and check the identification test pages.
A stitch defect is present
Y
N
Perform
SCP 5
Final Actions
Manually re-enable the IOD align calibration:
1.
Enter
dC131
NVM read/write NVM ID 490-41 and change value to 4.
2.
Enter
dC971
and start the routine.
3.
Enter
dC612
and print TP 16 and check the identification test pages.
A stitch defect is present
Y
N
Perform
SCP 5
Final Actions
Go to
91-698-00, 91-699-00, 91-706-00, 91-712-00, 91-718-00, 91-720-00, 91-729-00, 91-
730-00, 91-732-00
IOD Excessive Head Misalignment RAP.
Enter
dC612
and print TP 16 Stitch Identification and check that the print quality is good.
If the stitch defect is still present, swap the print heads around to move the artifact to the out-
side of the page.
ColorQube® 9303 Family
WARNING
91-852-00 to 91-854-00 Y Dot Position SVD Calculation
RAP
91-852-00 PQM: TRC Wait for Ypos SVD Complete.
91-853-00 PQM: Unif Wait for Ypos SVD Complete.
91-854-00 PQM: Ydp Wait for Ypos SVD Complete.
NOTE: The above codes were designed for tracking background software calibrations that run
during the boot-up of the machine. No service action is required.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
The above fault codes may initiate if machine activities are requested manually or automati-
cally during the calculation process. If the faults are persistent perform the following:
1.
Enter
dC122
Fault History. If necessary perform the relevant RAP.
2.
Switch off, then switch on the machine,
3.
If the fault is still present then re-load the software,
February 2013
91-848-00 to 91-851-00, 91-852-00 to 91-854-00
2-405
WARNING
GP
14. Disconnect the power cord. Electricity can cause
GP
14.
GP
4.