Rep 62.11 Exposure Lamp Ribbon Harness - Xerox ColorQube 9303 Series Service Manual

Table of Contents

Advertisement

2
Remove 1 screw and clip.
1
Disconnect the ribbon harness.
Figure 1 Removal of the LED exposure lamps
Replacement
1.
The replacement procedure is the reverse of the removal procedure.
2.
Ensure that the ribbon harness is routed flat on the under side of the scan carriage to
avoid rubbing on the scanner PWB cover. When re-connected, the metal contacts on the
ribbon cable must face down, away from the scan carriage.
3.
Perform
ADJ 62.1
Optics Cleaning.
ColorQube® 9303 Family
2
Remove 1
screw and clip.
1
Disconnect the ribbon harness.
3
Remove 2 screws,
then the LED
exposure lamp(s).
February 2013

REP 62.11 Exposure Lamp Ribbon Harness

Parts List on
PL 62.15
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the CVT glass,
REP
2.
Remove the CVT ramp and document glass assembly
3.
Remove the scanner PWB cover,
4.
Disconnect the exposure lamp ribbon harness, PJ926 on the scanner PWB,
Item
8.
5.
Figure
1. Remove the exposure lamp ribbon harness.
4-257
WARNING
GP
14. Disconnect the power cord
WARNING
62.3.
REP
62.3.
PL 62.16 Item 9
(three screws).
Repairs/Adjustments
REP 62.10, REP 62.11
PL 62.16

Advertisement

Table of Contents
loading