Xerox ColorQube 9303 Series Service Manual page 538

Table of Contents

Advertisement

Table 1 PEST codes and action
Code
Hard/Soft Action
99-840
Hard
Refer to
WD
9.9. Check the DC cabling to the X axis drive motor upper.
Measure the resistance at PJ102 on the marking unit driver PWB for an
open or short circuit and to the chassis for a short circuit.
If a fault is found, repeat the measurement at the X axis drive motor
upper. If a short is measured, the marking unit driver PWB may be dam-
aged and be reported as an 'open' error.
If short error is reported, the motor is drawing excessive power.
Install new components as necessary, X axis drive motor upper,
91.20 Item
5, marking unit driver PWB,
Refer to the
91-510-00, 91-511-00
Check the upper X axis drive motor.
99-841
Hard
Refer to
WD
9.9. Check the DC cabling to the X axis drive motor upper.
Measure the resistance at PJ102 on the marking unit driver PWB for an
open or short circuit and to the chassis for a short circuit.
If a fault is found, repeat the measurement at the X axis drive motor
upper. If a short is measured, the marking unit driver PWB may be dam-
aged and be reported as an 'open' error.
If short error is reported, the motor is drawing excessive power.
Install new components as necessary, X axis drive motor upper,
91.20 Item
5, marking unit driver PWB,
Refer to the
91-510-00, 91-511-00
Check the upper X axis drive motor.
99-842
Soft
Go to the
91-510-00, 91-511-00
the upper X axis drive motor.
99-843
Soft
Go to the
91-510-00, 91-511-00
the upper X axis drive motor.
99-845
Hard
Refer to
WD
9.11. Check the DC cabling to the X axis drive motor lower.
Measure the resistance at PJ303 on the marking unit driver PWB for an
open or short circuit and to the chassis for a short circuit.
If a fault is found, repeat the measurement at the X axis drive motor
lower. If a short is measured, the marking unit driver PWB may be dam-
aged and be reported as an 'open' error.
If short error is reported, the motor is drawing excessive power.
Install new components as necessary, X axis drive motor lower,
91.25 Item
5, marking unit driver PWB,
Refer to the
91-510-00, 91-511-00
Check the lower X axis drive motor.
99-846
Hard
Refer to
WD
9.11. Check the DC cabling to the X axis drive motor lower.
Measure the resistance at PJ303 on the marking unit driver PWB for an
open or short circuit and to the chassis for a short circuit.
If a fault is found, repeat the measurement at the X axis drive motor
lower. If a short is measured, the marking unit driver PWB may be dam-
aged and be reported as an 'open' error.
If short error is reported, the motor is drawing excessive power.
Install new components as necessary, X axis drive motor lower,
91.25 Item
5, marking unit driver PWB,
Refer to the
91-510-00, 91-511-00
Check the lower X axis drive motor.
Status Indicator RAPs
99-839-00 to 99-871-00
PL
PL 92.10 Item
4.
X Axis Motor Over Current RAP.
PL
PL 92.10 Item
4.
X Axis Motor Over Current RAP.
X Axis Motor Over Current RAP. Check
X Axis Motor Over Current RAP. Check
PL
PL 92.10 Item
4.
X Axis Motor Over Current RAP.
PL
PL 92.10 Item
4.
X Axis Motor Over Current RAP.
February 2013
Table 1 PEST codes and action
Code
Hard/Soft Action
99-847
Soft
Go to the
91-510-00, 91-511-00
the lower X axis drive motor.
99-848
Soft
Go to the
91-510-00, 91-511-00
the lower X axis drive motor.
99-860
Hard
Refer to
WD
sure the resistance at PJ660 on the IOD pre-amplifier PWB for an open
or short circuit and to the chassis for a short circuit.
If a fault is found, repeat the measurement at the IOD shuttle motor. If a
short is measured, the IOD pre-amplifier PWB may be damaged and be
reported as an 'open' error.
If short error is reported, the motor is drawing excessive power.
Install new components as necessary, IOD assembly,
Refer to the
91-513-00, 91-514-00, 91-581-00, 91-583-00
Error RAP. Check the IOD shuttle motor.
99-861
Hard
Refer to
WD
sure the resistance at PJ660 on the IOD pre-amplifier PWB for an open
or short circuit and to the chassis for a short circuit.
If a fault is found, repeat the measurement at the IOD shuttle motor. If a
short is measured, the IOD pre-amplifier PWB may be damaged and be
reported as an 'open' error.
If short error is reported, the motor is drawing excessive power.
Install new components as necessary, IOD assembly,
Refer to the
91-513-00, 91-514-00, 91-581-00, 91-583-00
Error RAP. Check the IOD shuttle motor.
99-863
Soft
Go to the
91-513-00, 91-514-00, 91-581-00, 91-583-00
RAP. Check the IOD shuttle motor.
99-864
Soft
Go to the
91-513-00, 91-514-00, 91-581-00, 91-583-00
RAP. Check the IOD shuttle motor.
99-870
Soft
Go to the
93-825-00, 93-892-00
Check the ink key plate motor.
99-871
Hard
Refer to
WD
sure the resistance at PJ406 on the media path driver PWB for an open
or short circuit and to the chassis for a short circuit.
If a fault is found, repeat the measurement at the ink key plate motor. If a
short is measured, the media path driver PWB may be damaged and be
reported as an 'open' error.
If short error is reported, the motor is drawing excessive power.
Install new components as necessary, ink key plate motor,
Item
14, media path driver PWB,
Refer to the
93-825-00, 93-892-00
RAP. Check the ink key plate motor.
2-514
X Axis Motor Over Current RAP. Check
X Axis Motor Over Current RAP. Check
9.22. Check the DC cabling to the IOD shuttle motor. Mea-
9.22. Check the DC cabling to the IOD shuttle motor. Mea-
Ink Key Plate Motor Over Current RAP.
8.4. Check the DC cabling to the ink key plate motor. Mea-
PL 1.15 Item
5.
Ink Key Plate Motor Over Current
ColorQube® 9303 Family
PL 94.15 Item
1.
IOD Drive
PL 94.15 Item
1.
IOD Drive
IOD Drive Error
IOD Drive Error
PL 93.10

Advertisement

Table of Contents
loading

Table of Contents