16-604-38 to 16-605-07 Could Not Register With Reg
Service RAP
16-604-38 Could not register with registration service
16-604-99 Could not register with registration service
16-605-07 Unable to register with registration service
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
14. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
1.
Switch off the machine, then switch on the machine,
2.
If the fault remains, reinstall software,
Status Indicator RAPs
16-604-38 to 16-605-07, 16-605-14, 16-605-105
WARNING
GP
14.
GP
4.
16-605-14, 16-605-105 Unable to Unregister As RPC
Service / RPC Call Failure RAP
16-605-14 RPC call failure to ESS registration service
16-605-105 Unable to unregister as RPC service during shutdown
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
1.
If a single occurrence, take no action.
2.
For multiple occurrences, switch off the machine, then switch on the machine,
3.
If the fault remains, reinstall software,