8.7 Configuring the converter
8.7

Configuring the converter

Overview
After carrying out the basic configuration of devices in the project, make the extended settings
for commissioning.
Description of function
The following areas are provided in display area "Parameterization":

• Basic parameterization

Here you can view the preassigned basic parameters of the converter, and if necessary you
can change individual values. If the motor brake is available, then you can also set that this
brake is forced open.
• Inputs/outputs
Here you can configure the digital inputs and outputs of the converter.
• Technology functions
Here you configure the basic positioner (EPOS) and pulse train output (PTO).
Note
Guided quick startup
You can also easily configure the settings of the basic parameterization and the digital inputs
using the guided quick startup (Page 253).
Note
Telegram configuration
You configure the telegrams used in the converter configuration in the inspector window in the
telegram configuration. The most important settings are listed in Chapter "Configuring
telegrams (Page 285)".
8.7.1
Basic parameterization
Overview
You can parameterize the following operating parameters in the basic setting:
• Device supply voltage
• Direction of rotation
• Speed limit
• Torque limit
276
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB